GENERAL SAFETY SUMMARY
KI23400/KI27400 UM-2
-
15 -
Kingfisher Two-Way Tester Laser Eye Safety Information
This information on laser eye safety compliance covers all standard
product variants.
Centre
λ
Visual laser
650±5 nm
Surface emitting LED
3
850 / 1300±50 nm
Infra-red laser
1310 / 1490 / 1550 / 1625 ±20 nm
Specified CW Output Power¹
650 nm visual laser
1.6 mW
850/1300 nm LED
3
0.01 mW
1310 / 1490/ 1550 / 1625 nm laser
0.5 mW
1310 / 1550 nm Laser 1 mW
International Standard IEC 60825-2 Ed. 3.2 & IEC 60825-1 Ed. 3.0
λ
Instrument Hazard Level
650 / 850 / 1300 / 1310 / 1490 / 1550 / 1625 nm
Class 1
USA Standards ANSI Z136.2 / 21 CFR 1040.10 (1995)
Labelling for this product defers to IEC 60825 as per CDRH Laser
Notices No. 50 (2007) & 56 (2019). Annual FDA reports are lodged by
Kingfisher.
Maximum permissible CW output power²
IEC 60825-2 (2011)
–
Class 1
650 nm, MM or SM fiber
1.95 mW
850 nm, MM or SM fiber
3
3.88 mW
1310 nm, MM fiber
77.8 mW
1310 nm, SM fiber
25.8 mW
1550 nm, SM fiber
10.2 mW
Note 1:
Specified CW output power is the optical power that the Source can produce at
its output connector. Refer to specification sheet for actual operating power.
Note 2:
Maximum permissible CW output power is the highest optical power that is
permitted within the appropriate laser class. Refer to specification sheet for actual
operating power
Note 3
: LED devices are no longer identified in the latest revision of IEC 60825-1 (2014).