94
TOS3200
SIGNAL I/O Connector
The SIGNAL I/O connector is the D-sub 25-pin connector on the rear panel.
The connector is used to control the starting and stopping of the test or monitor the TOS3200
status.
•
Connector on the TOS3200
Omron Corp. XM3B-2522 D-SUB 25-pin female connector, Screw M2.6 x 0.45
•
Complies connector (plug)
D-sub 25-pin male (with fix screw M2.6)
To prevent operation errors due to noise, use a shielded D-sub 25-pin connector and a cable
of length less than or equal to 3 m.
For information on how to obtain the consumable parts, contact your Kikusui agent or distributor.
For details on how to use the tools, read the catalog by Omron.
•
Wire and tool that are necessary to make the connection
SIGNAL I/O Specifications
Input signal
Low-active control input
High-level input voltage:
11 V to 15 V
Low-level input voltage:
0 V to 4 V
Low-level input current:
-5 mA maximum
Input time width:
5 ms minimum
Output signal
Open drain output
Output withstand voltage: 30 Vdc
Output saturation voltage: Approx. 0.7 V (25 °C)
Maximum output current: 400 mA (TOTAL)
WARNING
Possible electric shock. Turn off all equipment before connecting or disconnecting
cables.
Wire
Single wire:
∅
0.32 mm (AWG28) to
∅
0.65 mm (AWG22)
Twisted wire: 0.32 mm
2
(AWG22) to 0.08 mm
2
(AWG28)
Wire stripper
A wire stripper that matches the wires listed above
Содержание TOS3200
Страница 15: ...General Description This chapter gives an overview and describes the features...
Страница 20: ...20 TOS3200 Options This page has been intentionally left blank...
Страница 29: ...Panel Control Basics This chapter explains how to select items on the screen and how to enter values...
Страница 38: ...38 TOS3200 Panel Memory This page has been intentionally left blank...
Страница 67: ...Meter Mode Measurement This chapter explains the touch current measurement in Meter Mode Meter Mode Measurement...
Страница 73: ...Program Test This chapter describes how to create and edit sequence pro grams and how to execute the test...
Страница 105: ...Specifications This chapter gives the specifications and external dimensions...
Страница 115: ...Appendix A A List of Default Settings B System Settings C Protection Function D Troubleshooting...
Страница 129: ......