State Hold Timer (Active Low)
State Hold Timer (Active Low)
is the length of time that the AUX Output Status Message ports remain at the low level after
these ports go low level.
The AUX Output Status Message ports go high level when the amount of time configured in
State Hold Timer (Active
Low)
elapses.
If “Off” is configured in
State Hold Timer (Active Low)
, the timer is not activated. In this case, the AUX Output Status
Message ports remain at low level from when the AUX Output Status Message ports go low level until the transceiver
receives a Status Message which changes the AUX Output Status Message ports to high level.
Configuration using KPG-D1/ D1N
Configuring
State Hold Timer (Active Low)
(
Transceiver Settings > Extended Function > AUX > AUX Output >
AUX Output Status Message)
Status Memory (AUX Output Status Message)
Status Memory (AUX Output Status Message)
can be used to retain the output status of AUX Output Status Message 1
to AUX Output Status Message 3.
If this function is enabled, the output status of each of AUX Output Status Message 1 to AUX Output Status Message 3 is
retained. When the transceiver is turned ON, the transceiver restores the last status prior to the transceiver being turned
OFF (high level or low level).
If this function is disabled, the output status of each of AUX Output Status Message 1 to AUX Output Status Message 3 is
not retained and the port always goes high level when the transceiver is turned ON.
Configuration using KPG-D1/ D1N
Configuring
Status Memory (AUX Output Status Message)
(
Transceiver Settings > Extended Function > AUX >
AUX Output > AUX Output Status Message)