Section 2: General operation
Series 2200 Programmable DC Power Supplies Reference Manual
2-32
2200S-901-01 Rev. C / March 2016
To configure the third step in the list:
1. Input
S 003=
1.000
V
. Press
Enter
. The display shows
S 003= 0.0000A.
2. Input
S 003=
1.000
A
as the current limit. Press
Enter
. The display shows
S 003= 1.0000S.
3. Input
S 003=
1.000
S
as the duration of the step. The display shows
S 003= 0.001S
. Press
Enter
. The display shows
S 004= 0.000V
.
This completes the configuration of the third step. You are ready to configure the fourth step.
To configure the fourth step in the list:
1. Input
S 004=
7.000
V. Press
Enter
. The display shows
S 004= 0.0000A
2. Input
S 004=
3.000
A
as the current limit. Press
Enter
. The display shows
S 004= 1.0000A
.
3. Input
S 004=
0.001
S
as the duration of the step. The display shows
S 004= 0.001S.
Press
Enter
.The display shows
S 5= 0.000V
.
This completes the configuration of the fourth step. You are ready to configure the fifth step.
To configure the fifth step in the list:
1. Input
S 005=
3.000
V. Press
Enter
. The display shows
S 005= 0.0000A.
2. Input
S 005=
1.000
A
as the current limit. Press
Enter
.
S 003= 0.0001S.
3. Input
S 005=
0.001
S
as the duration of the step. Press
Enter
. The display shows
Save List 1
.
This completes the configuration of the fifth step.
To save the list to location 3:
Input
3
. Press
Enter
. This saves the list to location
3
. The display shows
>Edit List
.
The list is now complete and saved. You are ready to run the list.
To run the list:
1. Press
Output On/Off
to turn on the output.
2. Press
Shift
and
2
to display the available list.
3. Use the arrow keys, the navigation wheel , or the keypad to select
3
as the location of the saved
list.
4. Press
Enter
.
L3:EE
is displayed while the power supply waits for a trigger.
5. Press
Shift
and
3
to to run the list.
You are ready to stop running the list.
To stop running the list:
1. Press
Output On/Off
to turn off the output
2. Press
ESC
to exit the list mode.