Section 7: Command reference
Model 2651A High Power System SourceMeter® Instrument Reference Manual
7-322
2651A-901-01 Rev. A / March 2011
As an example, to set bit B0 of the system summary 4 enable register, set
status.system4.enable =
status.system4.enable.EXT
.
In addition to the above constants,
enableRegister
can be set to the numeric equivalent of the bit to set. To
set more than one bit of the register, set
enableRegister
to the sum of their decimal weights. For example, to
set bits B11 and B14, set
enableRegister
to 18,432 (which is the sum of 2048 + 16,384).
Bit
B7 B6 B5 B4 B3 B2 B1 B0
Binary
value
0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
Decimal
128 64 32 16 8 4 2 1
Weights (2
7
) (2
6
) (2
5
) (2
4
) (2
3
) (2
2
) (2
1
) (2
0
)
Bit
B15 B14 B13 B12 B11 B10 B9 B8
Binary
value
0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
Decimal
32,768 16,384 8,192 4,096 2,048 1024 512 256
Weights (2
15
) (2
14
) (2
13
) (2
12
) (2
11
) (2
10
) (2
9
) (2
8
)
Example 1
enableRegister = status.system4.
status.system4.NODE56
status.system2.enable = enableRegister
Sets bit B11 and bit B14 of the system
summary 4 enable register using
constants.
Example 2
-- decimal 18432 = binary 0100 1000 0000 0000
enableRegister = 18432
status.system4.enable = enableRegister
Sets bit B11 and bit B14 of the system
summary 4 enable register using a
decimal value.
Also see
System summary and standard event registers
status.system5.*
These attributes manage the status model's TSP-Link
®
system summary register for nodes 57 through 64.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Attribute
- -
- -
- -
- -
.condition (R)
Yes
Not applicable
Not saved
Not applicable
.enable (RW)
Yes
Status reset
Not saved
0
.event (R)
Yes
Status reset
Not saved
0
.ntr (RW)
Yes
Status reset
Not saved
0
.ptr (RW)
Yes
Status reset
Not saved
510 (All bits set)