Operators Manual
Section 8-6
Clockwise will decrease the output and
counterclockwise will increase the output.
(Remember the amount above was the output of four
tests.)
17.Clean out the graduated cylinder using the long
felt wick that is provided with the machine. A
thorough cleaning is important because any oil
left clinging to the sides of the cylinder will
give inaccurate readings.
NOTE
: When felt gets soaked with oil it can be
cleaned by squeezing it in a rag.
18.Repeat steps 8 through 17 to check any
adjustments that were made (i.e. If a change makes
the output too low, then unscrew the pump about
1/2 of the amount it was previously adjusted.)
19.Keep repeating the test until the amount in the
graduated cylinder reads
EXACTLY 16 mL
.
This calibration sets the machine to a
standard stream size of 40 microliters per board.
This allows us to “prove” the oil pattern that is
programmed into the machine.