MAINTENANCE
7-53
Replace Pilot Circuit Accumulator
--- every 4000 hours or once every two years
whichever comes first.
Consult your nearest authorized dealer for this service.
Check Ride Control Accumulator Function, Gas
Leakage, Looseness, and Damage
--- every 500 hours
WARNING: Allow only qualified personnel to handle
the accumulator.
y
High-pressure nitrogen gas is enclosed in the
accumulator. (N
2
is inert.)
y
Never strike the accumulator. Keep the accumulator
away from heat sources.
y
Do not weld the accumulator housing.
y
Be sure to release oil pressure before starting to
work on ride control circuit.
Let the machine travel with the ride control switch turned
from AUTO to OFF to compare the machine’s vertical vibration
during travel.
Travel the machine at the speed faster than “Ride Control Drive
Speed Setting” displayed on the multi-monitor.
If the machine’s vertical vibration is not dampened when
letting the machine travel with the ride control function
activated, the accumulator may be faulty.
Consult your nearest authorized dealer for check and repair.
Check Gas Pressure in Ride Control Accumulator
--- every 2000 hours
Check the gas pressure at a regular interval. Ask your nearest
authorized dealer for checking.
Check Gas Pressure in Steering Accumulator
--- every 2000 hours
Check the gas pressure at a regular interval. Ask your nearest
authorized dealer for checking.
While steering the machine, if you feel pulsation or vibration
and machine does not turn smoothly, contact your nearest
authorized dealer for the gas pressure checking.
MNDB-07-020
MNEC-07-069
MNEC-07-114
Содержание 70Z7
Страница 2: ...93108 00691 April 2015...
Страница 5: ......
Страница 11: ...MACHINE NUMBERS 2 MEMO...
Страница 51: ...SAFETY LABELS S 40 6 10 4 1 3 9 6 5 SS 3461...
Страница 171: ...OPERATOR S STATION 1 110 MEMO...
Страница 173: ...BREAK IN 2 2 MEMO...
Страница 187: ...OPERATING THE ENGINE 3 14 MEMO...
Страница 231: ...OPERATING THE MACHINE 5 24 MEMO...
Страница 359: ...MAINTENANCE 7 118 MEMO...
Страница 363: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 4 MEMO...
Страница 367: ...STORAGE 10 4 MEMO...