MAINTENANCE
7-51
1
2
3
4
5
Replace Air Breather Element
--- every 2000 hours
WARNING: Hydraulic oil becomes hot during
operation. Severe burns may result if skin comes in
contact with hot hydraulic oil. Wait for the oil to cool
before starting any maintenance work.
Replacement Procedures
1. Park the machine following the same procedures as
described on page 7-7 for preparation of inspection/
maintenance work.
2. Before replacing the filter element, be sure to relieve the
air pressure from the hydraulic oil tank by pressing air
bleed valve (1).
3. Rotate cover (3) clockwise approx. 1/4 turns. Remove cap
(2) by rotating it counterclockwise.
4. Rotate cover (3) counterclockwise and remove it.
Remove element (4).
5. Install new element (4). Tighten cover (3) clockwise.
After cover (3) come in contact with the inside element,
tighten the cover 1/4 turn further.
6. Manually tighten cap (2) clockwise to the end. Hold cap
(2) in position by hand to prevent the cap from turning.
Tighten cover (3) counterclockwise 5 to 10° securely.
7. Take care not to allow water or dust to enter the
clearance (air discharge port) between cover (3) and
body (5).
8. Replace the element at the recommended regular
intervals to keep the hydraulic oil clean and to extend
the service life of the hydraulic equipment.
M4GB-07-044
M4GB-07-166
Содержание 70Z7
Страница 2: ...93108 00691 April 2015...
Страница 5: ......
Страница 11: ...MACHINE NUMBERS 2 MEMO...
Страница 51: ...SAFETY LABELS S 40 6 10 4 1 3 9 6 5 SS 3461...
Страница 171: ...OPERATOR S STATION 1 110 MEMO...
Страница 173: ...BREAK IN 2 2 MEMO...
Страница 187: ...OPERATING THE ENGINE 3 14 MEMO...
Страница 231: ...OPERATING THE MACHINE 5 24 MEMO...
Страница 359: ...MAINTENANCE 7 118 MEMO...
Страница 363: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 4 MEMO...
Страница 367: ...STORAGE 10 4 MEMO...