DS Series PBX Technical Reference And Installation Guide
179
An E&M line can be extended to distances up to 2 km. with 0.5 mm. copper cable. That
distance can be extended even further by using thicker cables. However, it is extremely
important that there is no splice on the cable and it is supposed to be isolated from
environmental effects.
XV.3.Q. EX200 (4PLC/0) PLC LINE MODULE:
Pairs in the CBL-16 cable and connected lines have been stated in the table below.
Pair No
Color & Signal of the Pair
Line no
1
White (
E
) - Blue (
M
)
2
White (
A
) – Orange (
K
)
3
White (
T
) – Green (
T1
)
4
White (
R
) – Brown (
R1
)
PLC Line 1
5
White (
E
) – Gray (
M
)
6
Red (
A
) – Blue (
K
)
7
Red (
T
) – Orange (
T1
)
8
Red (
R
) – Green (
R1
)
PLC Line 2
9
Red (
E
) – Brown (
M
)
10
Red (
A
) – Gray (
K
)
11
Black (
T
) – Blue (
T1
)
12
Black (
R
) – Orange (
R1
)
PLC Line 3
13
Black (
E
) – Green (
M
)
14
Black (
A
) – Brown (
K
)
15
Black (
T
) – Gray (
T1
)
16
Yellow (
R
) – Blue (
R1
)
PLC Line 4
Regarding cabling of the PLC lines, order of both signaling and voice transmission wires
matters.
Those wires are supposed to be cross connected within their own groups.
Содержание DS200
Страница 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Страница 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Страница 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Страница 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Страница 80: ...70...
Страница 94: ...84 Type 4 Type 5 According to its position See the diagrams above for each type Upper PABX Lower PABX...
Страница 222: ...11 2010...