178
An E&M line can be extended to distances up to 2 km. with 0.5 mm. copper cable. That
distance can be extended even further by using thicker cables. However, it is extremely
important that there is no splice on the cable and it is supposed to be isolated from
environmental effects.
XV.3.P. EX200 (8E&M/0) E&M LINE MODULE:
Pairs in the CBL-16 cable and connected lines have been stated in the table below.
Pair No
Color & Signal of the Pair
Line no
1
White (
E
) - Blue (
M
)
2
White (
Tx
) – Orange (
Rx
)
E&M Line 1
3
White (
E
) – Green (
M
)
4
White (
Tx
) – Brown (
Rx
)
E&M Line 3
5
White (
Tx
) – Gray (
Rx
)
6
Red (E) – Blue (
M
)
E&M Line 4
7
Red (Tx) – Orange (Rx)
8
Red (
E
) – Green (
M
)
E&M Line 2
9
Red (
E
) – Brown (M)
10
Red (
Tx
) – Gray (
Rx
)
E&M Line 5
11
Black (
E
) – Blue (M)
12
Black (
Tx
) – Orange (
Rx
)
E&M Line 7
13
Black (
Tx
) – Green (Rx)
14
Black (
E
) – Brown (M)
E&M Line 8
15
Black (
Tx
) – Gray (
Rx
)
16
Yellow (E) – Blue (
M
)
E&M Line 6
Regarding cabling of the E&M lines, order of both signaling and voice transmission wires
matters.
Those wires are supposed to be cross connected within their own groups.
Order of wires has been stated in the table below for two corresponding exchanges:
Order of wires for an RJ45
on DS200 side
Signal
Order of wires on the
opposite side
1
E
M
2
M
E
3
Tx
Rx
4
Rx
Tx
Содержание DS200
Страница 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Страница 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Страница 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Страница 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Страница 80: ...70...
Страница 94: ...84 Type 4 Type 5 According to its position See the diagrams above for each type Upper PABX Lower PABX...
Страница 222: ...11 2010...