DS Series PBX Technical Reference And Installation Guide
139
1- BPL200-FC
4- Clock Master card
2- PCM cable connectors (RJ45)
5- BPL200-Main
3- PCM carrier cables (order matters)
After all cable connections have been completed, the card is pushed into the slot entirely and
one makes sure that the fixing latches that are on the plastic front cover have been fully fixed
on the metal chassis.
Then, the DS200 CPUKON, UTIL200, CPU200 cards and the redundant CPU200 card, if
there is one, of the main rack are installed in their corresponding slots, as explained in later
sections.
XII.1.C.1.2. HOW TO CONNECT THE BPLSPS-FCX CABLE:
The BPLSPS-FCX cable is structurally the same as the BPLSPS-FC cable, yet it is longer.
One end of that cable is attached to the SPS connector that is on the upper section of the
BPLSPS backplane of the third rack in the first cabinet.
The SPS248 Power Unit is installed in the corresponding slot afterwards, as explained in
later sections.
Finally, the free ends of the PCM carrier cables and the BPLSPS-FCX cable are inserted into
the second cabinet through the side cover gap that is on the lower back of the cabinet, and
they are extended until they reach the front face of the main rack.
Содержание DS200
Страница 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Страница 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Страница 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Страница 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Страница 80: ...70...
Страница 94: ...84 Type 4 Type 5 According to its position See the diagrams above for each type Upper PABX Lower PABX...
Страница 222: ...11 2010...