146
Physical Connections of the System
Figure below shows the Physical Connections of the DS200L System.
1) The connections between EX200 Utility 4E1 Card and DCC block are provided via metal
shielded one-to-one CAT5 STP cable
2) The connection between CC Card and network switch is provided via ethernet cable
3) The connection between maintenance computer and network switch is provided via
ethernet cable
4) The connection between PCU200 &redundant PCU200 and network switch is provided via
ethernet cable
5) The connection between DCC blocks and network switch is provided via ethernet cable
Connect the E1 lines coming from the TW200 towers to the 8E1 cards in DCC. Connect the
maintenance computer, the CC cards in the TW200 towers, the external power block and
PCU200 units to the network switch for maintaining TCP/IP connection. The DCC, the power
inverters and the SPS248 units are connected to the external power block. The PCU200 and
the network switch, on the other hand, are connected to external the power inverters and
receive the necessary voltage for their operation from the power inverters.
Содержание DS200
Страница 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Страница 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Страница 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Страница 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Страница 80: ...70...
Страница 94: ...84 Type 4 Type 5 According to its position See the diagrams above for each type Upper PABX Lower PABX...
Страница 222: ...11 2010...