170
XV.3.E. EX200 (CAS3B/0) CAS3B DIGITAL LINE
MODULE:
Pinouts pertaining to line connections of the EX200B (CAS3B/0) card have been stated in
the table below.
Signal
D-type Con. Pin no
RJ45 Pin no
R1
5
1
R2
9
2
T1
1
4
T2
6
5
Order of the 4 wires in the cable mentioned above matters, which are to be used for CAS3B
connection.
Pinouts for the cable that comes with the EX200 (CAS3B/0) module, have been stated in the
table below, with respect to the RJ45 connectors at both ends:
RJ45
Signal
RJ45
1
R1
4
2
R2
5
4
T1
1
5
T2
2
A CAS3B line can be extended to distances up to 100 meters with 0.5 mm. copper cable. In
case that distance is not sufficient, the range should be extended by employing HDSL
modems. Nevertheless, it is extremely important that there is no splice on the cable and it is
supposed to be isolated from environmental effects.
Содержание DS200
Страница 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Страница 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Страница 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Страница 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Страница 80: ...70...
Страница 94: ...84 Type 4 Type 5 According to its position See the diagrams above for each type Upper PABX Lower PABX...
Страница 222: ...11 2010...