XII.1. DS200
The DS200 system can be set up in two different structures, namely as “Wall” type or
“Cabinet” type. If the DS200 system consists of one or two racks at most, then it can be
mounted as wall type. On the other hand, the systems comprising three or more racks
definitely have to be mounted as cabinet type. The DS200 mechanical structure differs
according to the capacity of the system to be set up. Therefore, capacity is an essential
parameter that must be considered both while ordering and while installing the exchange.
XII.1.A. HOW TO SET UP THE WALL-TYPE DS200
SYSTEM
1- A location that complies with the requirements stated in the preparation step is plotted.
2- By making use of the mounting template that comes with the racks, the locations for the
wall mount bars that are to be used for hanging the racks on the wall are marked
carefully. The lower hole of the wall mount bars should be approximately 130 cm. above
the floor. It is essential to check whether the height of both holes are the same, in order
to make sure the exchange is parallel to the floor.
3- If there are two DS200 racks to be installed, then the lower hole of the wall mount bars of
the first rack (That would be the lower rack.) to be installed should be 100 cm. above the
floor.
4- The lower wall mount bar hole of the second rack is drilled 140 cm. above the floor,
vertically on the same line with the first one. When the installation is over, there should
be a 10-cm. gap between the two racks.
Содержание DS200
Страница 1: ...11 2010 TECHNICAL REFERENCE AND INSTALLATION GUIDE PBX DS SERIES...
Страница 2: ...DS SERIES PBX TECHNICAL REFERENCE AND INSTALLATION GUIDE NOVEMBER 2010...
Страница 17: ...DS Series PBX Technical Reference And Installation Guide 7...
Страница 69: ...DS Series PBX Technical Reference And Installation Guide 59...
Страница 80: ...70...
Страница 94: ...84 Type 4 Type 5 According to its position See the diagrams above for each type Upper PABX Lower PABX...
Страница 222: ...11 2010...