WATERCLEAN 1600
Version 03/2008
DESCRIPTION
- 31 -
2.3.7.2
Safety Fuses
The safety fuses are located on the inside of the left switch cabinet
wall. The integrated LED illuminates when the fuse is defective.
Fig. 23
Safety fuses
To change the safety fuse, tilt the respective fuse holder (24/1) down
to the front and remove the fuse from behind.
Fig. 24
Changing a safety fuse
1
Fuse phase control lamp 1
XF1
200 mA
2
Fuse phase control lamp 2
XF2
200 mA
3
Fuse phase control lamp 3
XF3
200 mA
4
Fuse 230V input in
Siemens module EM 223
XF4
1 A
5
Concentrate outlet valve V07
XF5
1.6 A
6
Drinking water outlet valve V08
XF6
1.6 A
7
Inlet magnetic valve V16
XF7
1.6 A
8
Reserve
XF8
1 A
1
Содержание WATERCLEAN 1600
Страница 2: ......
Страница 14: ...GENERAL Version 03 2008 WATERCLEAN 1600 8 ...
Страница 28: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 22 Fig 13 Anti scalant mounting kit 1 2 ...
Страница 48: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 42 ...
Страница 82: ...OPERATION Version 03 2008 WATERCLEAN 1600 76 ...
Страница 106: ...APPENDIX Version 03 2008 WATERCLEAN 1600 100 ...
Страница 108: ......
Страница 110: ......