OPERATION
Version 03/2008
WATERCLEAN 1600
- 58 -
➜
On the operating panel (49/7) the system output and pressure
data valid at the given time are shown
➜
"Control valve V06 closed" lamp (49/15) flashes, the control
valve automatically controls the system to the rated opera-
tional range (output 1 600 l/h or pressure 70 bar)
NOTE
Upon reaching the rated operational range the lamp
(49/15) goes out; re-adjustment is possible at any time.
NOTE
The connection for the level sensors of the drinking
water interim storage is located next to the socket
(41/3) for the raw water pump. This connection
must always be plugged in!
4.
Insert plug of the level sensor cable (41/1) into socket (41/2) on
the RO side.
Fig. 41
Connecting cable for float switch
5.
Turn float switch (49/3) to position "ON".
6.
➜
The system is switched ON and OFF via the float switch.
NOTE
Before turning the WTC 1600 unit off the switch
(49/3) has to be turned to position "OFF".
WARNING
It is absolutely imperative that the float switch is
set to ON for operation of the system. Otherwise
there is the danger of overfilling the drinking water
interim storage. When filling for the first time,
check if the maximum level sensor switches off
correctly.
2
1
3
Содержание WATERCLEAN 1600
Страница 2: ......
Страница 14: ...GENERAL Version 03 2008 WATERCLEAN 1600 8 ...
Страница 28: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 22 Fig 13 Anti scalant mounting kit 1 2 ...
Страница 48: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 42 ...
Страница 82: ...OPERATION Version 03 2008 WATERCLEAN 1600 76 ...
Страница 106: ...APPENDIX Version 03 2008 WATERCLEAN 1600 100 ...
Страница 108: ......
Страница 110: ......