DESCRIPTION
- 37 -
A password is necessary for changing the values preset by the manu-
facturer. Upon request the password is supplied by Kärcher.
2.3.9
UV Treatment
(Option)
The UV irradiator (26/1) is fastened on the frame of the RO module. For
reduction of germs, the drinking water is conducted through the UV
irradiator. The function of the UV irradiator is monitored by means of
an integrated sensor and signalized at the indication panel (26/2) of
the UV switch cabinet. The UV switch cabinet is installed in the RO mo-
dule, next to the cleaning tank. For operation, switch (26/3) must be set
to "Auto".
Fig. 26
UV irradiator, switch cabinet
17 Working hours
• Time since maintenance
• Working hours
Display
T i m e s i n c e m a i n t e -
n a n c e _ _ _ _ h
W o r k i n g h o u r s
_ _ _ _ h
18 Disinfection
• Disinfection times
• Disinfection indication
Display
D i s i n f e c t i o n t i m e
a c t 0 / s e t 3 0 m i n
D i s i n f e c t i o n P 0 2 / 2
r u n - t i m e 2 m i n
D i s i n f e c t i o n V 0 8
o p e n 1 0 m i n
D i s i n f . i n d i c a t i o n
o p e n V 1 0 2 0 m i n
Menu
Information
1
2
3
Содержание WATERCLEAN 1600
Страница 2: ......
Страница 14: ...GENERAL Version 03 2008 WATERCLEAN 1600 8 ...
Страница 28: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 22 Fig 13 Anti scalant mounting kit 1 2 ...
Страница 48: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 42 ...
Страница 82: ...OPERATION Version 03 2008 WATERCLEAN 1600 76 ...
Страница 106: ...APPENDIX Version 03 2008 WATERCLEAN 1600 100 ...
Страница 108: ......
Страница 110: ......