WATERCLEAN 1600
Version 03/2008
OPERATION
- 61 -
1.
Turn hand-wheel (43/1) slowly in the "CLOSE" direction until the
first adjustment value for Pass 1 is reached on the "Pass 1” menu
of the control panel.
Fig. 43
Hand-wheel
2.
Using button "
▼
" (44/3) on the operating panel, switch to menu
"Pass 2".
3.
Press button "2" (44/5) until the first adjustment value for Pass 2
is reached on the "Pass 2" menu.
If this value is exceeded, press button "4" (44/4) to reduce the
output value.
➜
NOTE
The adjusting procedure runs very slowly.
Fig. 44
Operating panel
4.
Using button "
▲
" (44/2) on the operating panel switch to menu
"Pass 1" and check/correct the output value.
• Turn hand wheel (43/1) in the "CLOSE" direction to increase
the output value
• Turn hand wheel (43/1) in the "OPEN" direction to reduce the
output value
5.
Repeat working steps 2. to 4. until the rated operation range is
reached. In so doing, adjust the
setting values
1
3
1
2
4
5