MULTICAL® 803
Kamstrup A/S · Technical description · 5512-2360_A1_GB_02.2019
93
6.6
Registers and resolution
Energy and volume counted in the meter count registers in MULTICAL® 803 are displayed in normal resolution in the
USER loop. Normal resolution is available in four levels according to the selected CCC code and flow sensor size. The
resolution levels are indicated in relation to selected display units in the table below.
Display
Normal resolution
High resolution
Resolution
level
MWh
Gcal
kWh
GJ
m
3
tons
kWh
l
3
0.0001
0.1
0.001
0.001
0.0001
0.001
2
0.001
1
0.01
0.01
0.001
0.01
1
0.01
-
0.1
0.1
0.01
0.1
0
0.1
-
1
1
0.1
1
Table 1_ Normal and high resolution for meter count registers, depending on the CCC code
Energy
Volume
Normal resolution
High resolution
Table 2:
Examples of normal and high resolution, flow sensor size qp 1.5 m³/h
While the calculator is in TEST loop, all integrations are carried out with 2 second interval regardless of whether the
calculator is supplied from mains supply or backup battery. The above high-resolution registers can also be seen in
the TECH loop, see paragraph 6.2.
While the calculator is in the TEST loop, high-resolution pulses for test purposes can be generated via the pulse
interface (see paragraph 13).