MULTICAL® 803
72
Kamstrup A/S · Technical description · 5512-2360_A1_
GB
_02.2019
By means of the calculator’s primary keys, you can choose from and switch between the four display loops. When
delivered, the calculator is in transport state, which means that the USER, TECH and SETUP loops are available.
Depending on country code, the access to the SETUP loop can be blocked in transport state and is thus not available
on delivery. The TEST loop can only be accessed if the test seal (verification seal) is broken.
By keeping the primary key activated for 5 seconds, the Select loop appears. Here, it is possible to use the arrow keys
to switch between the calculator’s display loops. In the TECH, SETUP and TEST loops, use index numbers as the views
in these display loops are allocated to a specific index number. The index numbers facilitate navigation to the
required reading. Index numbers are not used in the configurable USER loop. The figure below illustrates how it is
possible to navigate in the calculator’s display by means of the front keys.
Readings in case of error
In order to facilitate the diagnostics work, lines are shown in the display readings (current values) which are
influenced by the error and at the same time, counting stops in the registers, which are dependent on the given
parameter and thus influenced by the error. In case of an interrupted or short-circuited temperature sensor, the
corresponding display reading shows lines and energy calculations, which are dependent on the faulty
measurement, will stop. MULTICAL® 803 registers these errors and sets an info code, which can easily be read from
the display. Read more about the info codes in paragraph 7.8.
Display of t2 in case of temperature
sensor error
Display of differential temperature
t1-t2 in case of temperature sensor
error
Error in the display of power as a