MULTICAL® 803
58
Kamstrup A/S · Technical description · 5512-2360_A1_
GB
_02.2019
Automatic
To be stated in order
Default
Primary Address for M-Bus,
Modbus and BACnet
4
-
Address 0-250
Last 2-3 digits of
customer number
M-Bus ID No.
(used for secondary address)
-
-
Customer no.
wM-Bus ID no.
-
-
Serial number
Offset of t1, t2, t3, t4 (± 0.99K)
4
(See paragraph 7.3)
To be entered on the
basis of R
0
of the
sensor element as well
as the cable resistance.
If no sensor data is
available, offset is set
to 0.00 K.
-
-
t2 preset
Only active if meter types 4 and 9
are selected.
-
0,01…185.00
°
C + 250.00
°
C 250.00
°
C
t3 preset
-
0,01…185.00
°
C + 250.00
°
C 250.00
°
C
t4 preset
-
0,01…185.00
°
C + 250.00
°
C 250.00
°
C
t5 preset
Only relevant for meter types 1
and 2. (See paragraph 7.1.3)
-
0.01…185.00
°
C
50.00
°
C
Scheduler profile
(See paragraph 7.13)
-
Created scheduler profiles
Depends on the country
code
(Disabled by default)
DST
(Daylight Saving Time)
(See paragraph 7.12)
-
Enabled / Disabled
Depends on country
code
1
Serial no. (factory-set unique serial number) is written on the calculator and cannot be changed after factory
programming.
2
Yearly target date 2 (MM.DD) and monthly target date 2 (DD) set to 00.00 and 00, respectively. If these target dates
are disabled, the calculator just uses yearly target date 1 and monthly target date 1.
3
θ
hc
= 250.00
°
C disconnects the function. In all other meter types than 6,
θ
hc
is disabled and cannot be enabled after
delivery.
4
At order submission, you can select “fixed address”, which means that all calculators included in the order will be
configured with the same primary address.
5
R
0
is the resistance value of the sensor element in ohm (Ω) at 0 °C.