MULTICAL® 803
74
Kamstrup A/S · Technical description · 5512-2360_A1_
GB
_02.2019
Heart beat and status indications
MULTICAL® 803 uses the three small display segments in the lower left corner of the display to indicate different
status scenarios. Each segment will, depending on whether it is static or flashes, provide information about given
functionality in the calculator. A description can be found in the figure below:
① Heart beat segment
Flashes - This segment always flashes to indicate that both calculator and
display are active.
② SETUP and config segment
Permanently on - The calculator’s configuration log is full and it is therefore
no longer possible to modify the configuration.
Flashes - It is possible to access the SETUP loop. The segment flashes as long
as the calculator is in transport mode or 4 minutes after the calculator top
and base have been separated.
Off - It is not possible to access the SETUP loop or configure the calculator via
METERTOOL HCW.
③ Optical interface segment
1
Permanently on - The calculator’s optical interface is disabled and optical
communication is therefore not possible.
Flashes - The optical interface is temporarily active, flashes 4 minutes after
the calculator top and base have been separated. In this period, it is possible
to activate the optical interface permanently.
Off - The optical interface is active and it is possible to communicate with the
calculator.
1
The optical interface can be deactivated and activated via the optical read-out head and METERTOOL HCW. See the
technical description of METERTOOL HCW (5512-2097).