MULTICAL® 302
72
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
14.2
Test connection
During test either optical reading head with USB plug (66-99-099) for serial reading of high-resolution energy and
volume registers, or Pulse Interface (66-99-143) with optical reading head and connection unit for high-resolution
pulse outputs is used. Do not forget that the meter must be in Test mode.
14.2.1
Verification pulses
When Pulse Interface type 66-99-143 is connected to power supply
or battery, the unit is placed on the meter, and the meter is in test
mode, the following pulses are transmitted:
• High
-resolution energy pulses (1 Wh/pulse) on terminals 7 and 8
• High
-resolution volume pulses (10 ml/pulse) on terminals 4 and 5
Pulse Interface 66-99-143, technical data
Supply voltage
Current consumption
Pulse outputs
Pulse duration
Energy pulse
Volume pulse
3.6 – 30 VDC
<
15 mA
<
30 VDC
<
15
mA
3.9 ms.
1 Wh/pulse (1000 pulses/kWh)
10 ml/pulse (100 pulses/litre)