Display functions
MULTICAL
302 is fitted with an easily readable LC-display comprising 8 digits, measuring units and an information
field. Energy and volume readings use 7 digits and corresponding measuring units, whereas 8 digits are used to
display e.g. the meter number.
If the push-button has not been activated for 4 minutes, the display switches off. When the display is off, three lines
will appear in the right side of the display every 32 seconds in ”normal mode” or every 8 seconds in ”fast mode”. In
order to activate the display you press the push-button.
Basically accumulated energy is displayed. Activating the push-button, the display immediately switches to other
readings. The display automatically returns to energy reading four minutes after the latest activation of the push-
button, and after four more minutes without activation of the push-button the display switches off in order to save
current.
The meter uses four different loops for four different user situations: User loop, Tech loop, Setup loop and Test loop. It
is only possible to display one loop at a time.
8.1
Select display loop
By means of the push-button on the front of the meter you can choose between four display loops. No matter which
display you have selected you can change to User-loop by pressing the push-button for 5 s until
”1-User” is displayed and then releasing the button. If the button is pressed for 7 s instead, ”2-Tech” is displayed, and
if you release the push-button now, you have access to Tech loop.
When you receive the meter it is in "Transport State", from which you access Setup loop (depending on country code)
by pressing the push-button for 9 seconds and then releasing the button. When the meter has registered its first
volume accumulation, either 0.01 m
3
(10 L) or 0.001 m
3
(1 L) – determined by selected resolution, the meter changes
from ”Transport State” to ”Normal State”, from which Setup loop cannot be accessed unless the seal at the back of the
meter is broken and the installation switch activated.
There is only access to Test loop if the Test seal is broken and the Test switch activated.