MULTICAL® 302
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
21
3.6
CONFIG >EFGHHMMM<
The configuration can only be changed via METERTOOL HCW provided that the seal is broken and the switch activated.
E
- F
- G
- HH
- MMM
Info codes
Dynamic (Info codes are automatically deleted when the error has been remedied)
1
Static (Info codes can only be deleted by means of METERTOOL HCW)
2
Wired M-Bus protocol
Standard frame format *)
3
wM-Bus Encryption
Encryption with common (customer) key
2
Encryption with individual key
3
wM-Bus protocol
Mode C1 according to EN 13757 (16 s interval), yearly target data
01
Mode C1 according to EN 13757 (16 s interval), monthly target data
02
Mode C1 according to EN 13757 (16 s interval), yearly target data incl. E8 and E9
11
Mode C1 according to EN 13757 (16 s interval), monthly target data incl. E8 and E9
12
Mode T1 OMS (900 s interval), yearly target data
03
Mode T1 OMS (900 s interval), monthly target data
04
Customer label 2012-MMM
000
*) Monthly data is transmitted by default. Change to yearly data possible by means of an M-Bus command.
For further details we refer to the Technical description of M-Bus for MULTICAL
®
302.
Note:
Green marking indicates standard.
3.6.1
Customer label
In lower middle part of the meter an area of 15 x 38 mm is reserved for customer labels, e.g. utility logo, bar code,
serial number or similar according to customer requirements. Unless otherwise specified in the order, MULTICAL
®
302
will be supplied with customer label no. 2012-000, which comprises the meter’s customer number.