MULTICAL® 302
12
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
2.3
Mechanical data
Environmental class
Fulfils EN 1434 class A (MID class E1) and class M2
Protection
class
Ambient
temperature
Environmental class
Calculator
IP65
5…55 °C
Non-condensing
Indoors (closed position)
Flow sensor and sensor pair
IP68
Condensing
Medium temperatures
Heat meters 302-T
2…130 °C
At medium temperatures below 15 °C the calculator must be wall
mounted in order to prevent condensation.
At medium temperatures above 90 °C in the flow sensor the
calculator must be wall mounted in order to prevent too high
temperature, especially in relation to display and battery lifetime.
Cooling meters 302-T
2…130 °C
Heat/cooling meters 302-T
2…130 °C
Medium in flow sensor
Water
Storage temperature
-25…60 °C (drained flow sensor)
Pressure stage (with thread) PN16 and PN25
Weight
From 0.7 to 1.1 kg depending on flow meter size and extension piece
Flow sensor cable
1.2 m (undemountable cable)
Temperature sensor cables
1.5 m (undemountable cables)