3.2
Type number composition
Type 302-
Basic version
Pt500 sensor input
T
Communication
No communication
00
M-Bus (comes with 1.5 m factory mounted cable)
20
M-Bus (comes with 2.0 m factory mounted cable)
21
Wireless M-Bus, 868 MHz (configurable mode C1 or T1)
30
Supply
6-8 year battery, Normal Response meter
1
12-16 year battery, Normal Response meter
2
6-8 year battery, Fast Response meter
3
Temperature sensors
Pt500, ø5.2 mm temperature sensors with cable length 1.5 m and composite union
Q9
Pt500, ø5.2 mm temperature sensors with cable length 1.5 m and brass union
QF
Flow sensor qp
[
m
3
/h
]
Connection
Length
[mm]
0.6
G¾B (R½) 110
10
DN15
With extension to 130 mm
11
With extension to 165 mm
12
1.5
G¾B (R½) 110
40
DN15
With extension to 130 mm
41
With extension to 165 mm
42
1.5
G1B (R¾) 130
70
DN20
With extension to 190 mm
71
With extension to 220 mm
72
2.5
G1B (R¾) 130
A0
DN20
With extension to 190 mm
A1
With extension to 220 mm
A2
Meter type
Heat meter (MID module B+D)
θ
hc
= OFF
2
Heat/cooling meter (MID module B+D & TS27.02+DK268)
θ
hc
= OFF
3
Heat meter (National approval)
θ
hc
= OFF
4
Cooling meter (TS27.02+DK268)
θ
hc
= OFF
5
Heat/cooling meter
θ
hc
= ON
6
Country code
(language on label etc.)
XX
The flow sensors are type approved for dynamic ranges q
p
:q
i
= 250:1 and 100:1, but basically 100:1 is supplied.