MULTICAL® 302
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
51
8.4
SETUP loop
Setup loop comprises everything that can be changed in the meter. Setup loop is no longer available, when the meter
has registered its first volume accumulation or if you exit via the ”EndSetup” function.
Setup-loop can be enabled again by breaking the seal and activating the switch. In that case Setup is locked by
”EndSetup” or automatically 4 min. after the last activation of the button.
In Setup-loop selected configurations of the meter can be changed:
-Customer number
-Date
-Time
-Target date
-Flow sensor position (inlet/outlet)
-Energy unit
-Primary M-Bus address
-Average peak time max./min.
-Heat/cooling switching
-Radio (on/off)
Setup
When delivered the meter is in transport state, which means
that display loop ”Setup” is available.
Setup loop is selected by activating
the button continuously for 9 s
until ”SETUP” is displayed.
The meter remains in Setup loop until the front button is
pressed for 5 s however, a time-out secures that the meter
reverts from Setup loop to User loop after 4 minutes.
Transport state ends when the meter has registered its first
volume accumulation, either 0.01 m
3
(10 L) or 0.001 m
3
(1 L) –
determined by the selected resolution.
When the meter has left transport state, Setup-loop is no longer
available, unless the
SETUP seal is broken and the contact
points behind the seal short-circuited with short-circuit pen type
66-99-278.
The seal must be re-established with a void label size 15 x 15
mm (Kamstrup's seal no. 2008-727 can be used). The seal is
important with a view to the meter's approval and to
maintaining its protection class.
Note
: The option Setup has been deselected on certain country codes.