MULTICAL® 302
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
19
3.3
Config. >A-B<
The legal parameters of the meter are determined by Config., which can only be changed before installation when the
meter is still in transport state, or after breaking the seal ”I (SETUP)” and activating the switch.
The
code A
indicates installation of the flow sensor in inlet or outlet pipe. As the density and specific heat capacity of
water varies with temperature, the calculator must compensate for the installation type in question. Wrong
configuration or installation will result in a measuring error. Further details on installation of flow sensor in inlet and
outlet as far as heat and cooling meters are concerned appear from section 6.6.
The
code B
indicates the measuring unit used for energy registration, GJ, kWh or MWh, as well as the display
resolution.
A
- B
Flow sensor position
Inlet
3
Outlet
4
Measuring unit and resolution
00000.01 GJ
00000.01 m³
2
0000.001 GJ
0000.001 m³
6
0000001 kWh
00000.01 m³
3
000000.1 kWh
0000.001 m³
7
0000.001 MWh
00000.01 m³
4