MULTICAL® 302
Kamstrup A/S · Technical Description · 5512-1334_F1_GB_12.2016
45
7.7.3
Info-event-counter
Enumeration takes place every time the info code is
changed (the info code is added to the info-event
counter and data logged when it has remained
present for minimum an hour).
The info-event counter of a new meter will be 0 as
“transport state” prevents counting during trans-
portation.
Info code
”info” in display
Registration in info,
hourly, daily, monthly and
yearly logger
Enumeration of Info-event
1
No
Yes
Upon each ”Power-On-Reset”
4, 8
Yes
Yes
When Info 4 or 8 is set or removed
16, 2
Yes
Yes
When Info is set and when Info is deleted
32
Yes
Yes
At wrong temperature difference
128
Yes
Yes
Battery voltage below 3.0 VDC
7.7.4
Transport state
The meter leaves the factory in transport state, i.e. the info codes are active in the display, but not in the data logger.
This prevents ”info-event” from counting during transportation and non-relevant data from appearing in the info
logger. The first time the meter enumerates the volume register after installation, the info code automatically becomes
active in the data logger (after one hour).
If the meter has built-in wM-Bus communication, the radio transmitter will be switched off when the meter is in
transport state.