7.8
Data loggers
MULTICAL
302 has a permanent memory (EEPROM), in which the results from various data loggers are saved. The
meter includes the following data loggers:
Data logging interval
Data logging depth
Logged value
Yearly logger
15 years
Counter register
Monthly logger
24 months
Counter register
Daily logger
460 days
Counter register
Hourly logger
960 hours
Counter register
Info logger
50 Events (36 events can be displayed)
Info code and date
Config. logger
25 config. changes
New config. and date
Loggers are static ones. Therefore, register types and logging intervals cannot be changed. When the last record has
been written into the EEPROM the oldest one will be overwritten.
The meter only permits 25 reconfigurations, which means that the config. logger cannot be overwritten (unless the seal
is broken).
7.8.1
Yearly, monthly, daily and hourly loggers
The following registers are logged every year and every month on target date. Furthermore, the daily registers are
logged at midnight and the hourly registers are logged every hour.
All the below registers are logged as counter registers.
Register type
Description
Yearly
logger
Monthly
logger
Daily
logger
Hourly
logger
Date (YY.MM.DD.hh)
Logging time: year, month, day and hour
•
•
•
•
E1
Heat energy
•
•
•
•
E3
Cooling energy
•
•
•
•
E8
E8=m
3
x T1 (inlet)
•
•
-
-
E9
E9=m
3
x T2 (outlet)
•
•
-
-
V
Volume register
•
•
•
•
INFO
Information code
•
•
•
•
h
Hour counter
•
•
-
-
h-INFO
Error hour counter
•
•
-
-
DATE FOR MAX. FLOW
Date stamp for max. flow during period
•
•
-
-
MAX. FLOW
Value of max. flow during period
•
•
-
-
DATE FOR MAX. POWER
Date stamp for max. power during period
•
•
-
-
MAX. POWER
Value of max. power during period
•
•
-
-