rp [bar]
i.Comp 3
—
—
Q
min
Q
max
Q
min
Q
max
Q
min
Q
max
11.0 (rp
max
)
—
—
—
—
—
—
Flow rate in accordance with ISO 1217:2009, Annex E
Tab. 6 Flow rate 100 – 127V / 11,0 bar
2.4.2 Flow rate Q [l/min] at maximum required pressure of 11 bar:
Rated voltage 200 – 240V / 1 / 50/60Hz
pA [bar]
i.Comp 3
—
—
Q
min
Q
max
Q
min
Q
max
Q
min
Q
max
pA
min
100
170
—
—
—
—
6.0
85
160
—
—
—
—
11.0 (pA
max
)
65
117
—
—
—
—
Flow rate in accordance with ISO 1217:2009, Annex E
Tab. 7 Flow rate 200 – 240V / 11,0 bar
2.5 Ambient conditions
Installation
Maximum eleva‐
tion AMSL
1)
[m]
1000
Permissible ambient tem‐
perature [°C]
3–35
1)
Higher altitudes are permissible only after consultation with the manufacturer.
Tab. 8 Ambient conditions
2.6 Ventilation
The values given are minimum guide values that must be maintained.
Compressor model
Inlet aperture (Z) [m
2
]
Exhaust fan (A)
1)
[m
3
/h]
i.Comp 3
0.4
720
—
—
—
1)
Forced ventilation: required air volume for exhaust fan at static compression 1 mbar and max.
duty cycle (ΔT≙10 K)
Tab. 9 Ventilation
2
Technical Specifications
2.5
Ambient conditions
6
Operator manual Reciprocating compressor
i.Comp 3
No.: 901731 24E
Содержание i.Comp 3
Страница 2: ...Original instructions KKW PWPC 2 04 en SBA KOLBEN ANLAGE M 20200310 081012...
Страница 6: ...Contents iv Operator manual Reciprocating compressor i Comp 3 No 901731 24E...
Страница 8: ...List of Illustrations vi Operator manual Reciprocating compressor i Comp 3 No 901731 24E...
Страница 10: ...List of Tables viii Operator manual Reciprocating compressor i Comp 3 No 901731 24E...