2. Pull the hose coupling forward.
3. Pull out the pressure hose towards the front.
6.5 Connecting the machine to the power supply network
Precondition The machine is isolated from the power supply network by means of the power supply isolating de‐
vice (plug/plug connection).
1. Carry out safety measures as stipulated in relevant regulations (e.g. IEC 364 or
DIN VDE 0100) and in applicable national accident prevention regulations (BGV A3 in Germa‐
ny). In addition, observe the regulations of the local electricity supplier.
2. Test the overcurrent protection device (backup fuse) to ensure that the time it takes to discon‐
nect in response to a fault is within the permitted limit.
3. Select fuse ratings in accordance with local regulations.
4. The tolerance limits of the mains voltage (power supply network) are within the permissible tol‐
erance limits of the rated voltage (machine).
5. DANGER!
Danger of fatal injury from electric shock!
➤ Secure against unintentional reactivation and verify the absence of voltage.
6. Connect the machine to the power supply network by means of the power supply isolating de‐
vice (plug/plug connection).
If voltage is applied to the machine, a lamp test is carried out.
If the LED “ON” flashes in green after this test, the macchine starts automatically when pres‐
sure is required.
You can switch off the machine during the flashing sequence by pressing the «OFF» key.
The network pressure is displayed.
6
Installation
6.5
Connecting the machine to the power supply network
28
Operator manual Reciprocating compressor
i.Comp 3
No.: 901731 24E
Содержание i.Comp 3
Страница 2: ...Original instructions KKW PWPC 2 04 en SBA KOLBEN ANLAGE M 20200310 081012...
Страница 6: ...Contents iv Operator manual Reciprocating compressor i Comp 3 No 901731 24E...
Страница 8: ...List of Illustrations vi Operator manual Reciprocating compressor i Comp 3 No 901731 24E...
Страница 10: ...List of Tables viii Operator manual Reciprocating compressor i Comp 3 No 901731 24E...