Basic safety instructions are found in this service manual at the beginning of each chapter in the
section entitled 'Safety'.
Warning instructions are found before a potentially dangerous task.
3.5.1 Safely dealing with sources of danger
The following describes the various forms of danger that can occur during machine operation.
Electricity
Touching voltage-carrying components can result in electric shocks, burns or even death.
➤ Allow only qualified and authorised electricians or trained personnel under the supervision of a
qualified and authorised electrician to carry out work on electrical equipment according to elec‐
trical engineering rules.
➤ Before commissioning or re-commissioning the machine, the user must ensure adequate pro‐
tection against electric shock from direct or indirect contact.
➤ Before starting any work on electrical equipment:
Switch off and lock out the power supply isolating device and verify the absence of any volt‐
age.
➤ Switch off any external power sources.
These may include devices connected to the floating contacts.
➤ Use fuses corresponding to machine power.
Compressive forces
Compressed air is contained energy. Uncontrolled release of this energy can cause serious injury
or death. The following information concerns work on components that could be under pressure.
➤ Close shut-off valves or otherwise isolate the machine from the distribution network to ensure
that no compressed air can flow back into the machine.
➤ Fully de-pressurise all pressurised components and enclosures.
➤ Do not carry out welding, heat treatment or mechanical modifications to pressurised compo‐
nents (e.g. pipes and vessels) as this influences the components' resistance to pressure.
The safety of the machine is then no longer ensured.
Compressed air quality
The composition of the compressed air must be suitable for the actual application in order to pre‐
clude health and life-threatening dangers.
➤ Use appropriate systems for compressed air treatment before using the compressed air from
this machine for the processing of foodstuffs.
Spring forces
Check valve, venting and unloading valve are spring-loaded.
➤ Do not open or dismantle any valves.
Rotating components
Touching the fan while the machine is switched on can result in serious injury.
➤ Do not open the housing while the machine is switched on.
➤ Switch off and lock out the power supply isolating device and check that no voltage is present.
3
Safety and Responsibility
3.5
Dangers
12
Operator manual Reciprocating compressor
i.Comp 3
No.: 901731 24E
Содержание i.Comp 3
Страница 2: ...Original instructions KKW PWPC 2 04 en SBA KOLBEN ANLAGE M 20200310 081012...
Страница 6: ...Contents iv Operator manual Reciprocating compressor i Comp 3 No 901731 24E...
Страница 8: ...List of Illustrations vi Operator manual Reciprocating compressor i Comp 3 No 901731 24E...
Страница 10: ...List of Tables viii Operator manual Reciprocating compressor i Comp 3 No 901731 24E...