1. Switch on the power supply isolating device (plug/plug connection).
The lamp test is carried out for 2 seconds. Subsequently, the network pressure is displayed.
2. Connect the machine to compressed air consumers.
3. Press the «ON» key
The green
ON LED lights continuously.
If the network pressure is lower than the cut-in pressure, the compressor motor starts running
and provides compressed air. The relief and load valve closes.
7.5 Adjusting the required pressure
The required pressure is preset at the factory.
It may be required to adjust the pressure to the individual operating conditions.
By pressing the «UP» or «DOWN» key for longer the required pressure can be adjusted in larger
steps.
Do not set the machine's required pressure higher than the maximum gauge working pres‐
sure of the connected compressed air consumers.
Precondition The power supply isolating device (plug/plug connection) is switched on.
1. Press the «UP» or «DOWN» key.
The required pressure and the set pressure unit are displayed.
2. Adjust the required pressure using the «Up» or «Down» keys.
3. The new required pressure value is flashing on the display.
If one of the keys isno longer pressed, the new required pressure is applied after a short time
and the network pressure is shown again.
7
Initial Start-up
7.5
Adjusting the required pressure
No.: 901731 24E
Operator manual Reciprocating compressor
i.Comp 3
31
Содержание i.Comp 3
Страница 2: ...Original instructions KKW PWPC 2 04 en SBA KOLBEN ANLAGE M 20200310 081012...
Страница 6: ...Contents iv Operator manual Reciprocating compressor i Comp 3 No 901731 24E...
Страница 8: ...List of Illustrations vi Operator manual Reciprocating compressor i Comp 3 No 901731 24E...
Страница 10: ...List of Tables viii Operator manual Reciprocating compressor i Comp 3 No 901731 24E...