PROCOLD S.r.l. - ITALY- 13043 CIGLIANO (VC)
C/so Umberto,58 - Tel (+39) 0161 42 44 52 Fax (+39) 0161 42 40 92
www.procold.it
info@proco ld.it
TD35 VS - TD50 VS
Technical specifications
Compressor for R134a 12/24V DC
Страница 1: ...PROCOLD S r l ITALY 13043 CIGLIANO VC C so Umberto 58 Tel 39 0161 42 44 52 Fax 39 0161 42 40 92 www procold it info procold it TD35 VS TD50 VS Technical specifications Compressor for R134a 12 24V DC ...
Страница 2: ...rpm Capacity W Input Power W Operating Current A C O P W W 1 1 Sound Level dB A Vibrancy Acceleration m s2 0 65 Operating Voltage V DC Cooling Static or Fan cooling Lubricant Polyester Lube Vol ml 5 Weight kg 4 3 Weight of Controller kg 0 40 Motor Type BLDCM Refrigerant R134a Throttling Device Capillary Power V D C 12 24 Test conditions Evaporating Temp 23 3 Suction Temp 32 2 Condensing Temp 54 4 ...
Страница 3: ...are using 5 1 7 A Thermostat is connected between the termin al C and T of the electronic unit It will start or stop the running of compressor automatically 5 1 8 A Resistor can be connected between terminal C and T it allows you to adjust the speed of the compressor the relationship between the resist or and the compressor speed shown by Table 3 please see it in page 3 5 1 9 To ensure sufficient ...
Страница 4: ...ltage V 0 9 6 10 9 17 0 21 3 22 7 31 5 1 6 9 7 11 0 17 0 21 5 22 9 31 5 2 4 9 9 11 1 17 0 21 8 23 2 31 5 3 6 10 0 11 3 17 0 22 0 23 4 31 5 4 7 10 1 11 4 17 0 22 3 23 7 31 5 6 2 10 2 11 5 17 0 22 5 23 9 31 5 8 2 10 4 11 7 17 0 22 8 24 2 31 5 11 10 5 11 8 17 0 23 0 24 5 31 5 14 10 6 11 9 17 0 23 3 24 7 31 5 18 10 8 12 0 17 0 23 6 25 0 31 5 24 10 9 12 2 17 0 23 8 25 2 31 5 33 11 0 12 3 17 0 24 1 25 5...
Страница 5: ...he refrigeration system has been too heavily loaded or if the ambient temperature is high than 55 the controller will run too hot 4 Minimum motor speed error if the refrigeration system is too heavily loaded the motor speed is lower than 1850 rpm 3 Motor start error The rotor is blocked or the system pressure is too high 2 Fan over current cut out The operating current of cooling fan is more than ...
Страница 6: ...ressor the pressure in the compressor could not more than 0 49MPa 8 6 Do not operate the compressor before polyester is charged 8 7 The refrigerant charge should be less than 200g 8 8 The interval of compressor operation Operation is more than 3 minutes and the stoppage is more than 3 minutes too 8 9 Special attention Do not use the compressor as a vacuum pump and do not start it under vacuum stat...
Страница 7: ...VS TD50 VS PROCOLD S r l ITALY 13043 CIGLIANO VC C so Umberto 58 Tel 39 0161 42 44 52 Fax 39 0161 42 40 92 6 www procold it info procold it CONTROLLER COMPRESSOR PROCESS Ø 6 20 SUCTION Ø 6 20 DISCHARGE Ø 5 15 DIMENSIONS COMPRESSOR Rev 2 0 27 02 2019 ...