background image

1

Thank you for choosing the 

TD35 VS

 and 

TD50 VS 

R134a 12/24V DC compressor.

Please read this manual thoroughly before beginning  operation. 

1 Application range 

         Suitable  for  the  cooling  device  with a power o f 12 or 24V DC power supply , Evaporating 

Temperature at -35

-5 , especially for using  in a mobile applications,  the refrigerant is R134a.

2 Features 

2.1.Easy start, High reliable.
2.2.Low noise,  Low vibrancy , long use life.
2.3.Attached Controller, Few attachment, Easy to use.
2.4.Rotary speed at 2000 rpm 

 3500rpm adjustable.

3 Type 

       Hermetic  reciprocating  refrigeration  compressor .

4 Technical Data 

Table  1  Specification  

Compressor Model 

Displacement,  cm

3

2.0 

Applications

                                       

       LBP

Rotation, rpm

Capacity, W

Input Power, W

Operating Current, A

C.O.P, W/W

1.1 

Sound Level, dB(A)

Vibrancy Acceleration,  m/s

2

0.65 

Operating Voltage, V DC

Cooling 

                Static or Fan cooling 

Lubricant

                                 Polyester

Lube Vol. , ml  

Weight , kg

4.3 

Weight of Controller, kg

0.40 

Motor Type 

BLDCM 

Refrigerant

                                  R134a

 

Throttling Device 

             Capillary 

Power, V D C

12/24 

Test conditions

     Evaporating  Temp

-23.3

                         Suction. Temp.               32.2

Condensing  Temp.         54.4  

Sub-cooling  Temp.        32.2 

Ambient  Temp.              32.2  

Notes

*

base on the input power of 12V DC 

COLDEX 

TD35 VS

PROCOLD S.r.l. - ITALY- 13043 CIGLIANO (VC)

C/so Umberto,58 - Tel (+39) 0161 42 44 52 Fax (+39)  0161 4 2 40 92 
                     www.procold.it      info@proco ld.it

Rev. 2.0 27/02/2019

COLDEX 

TD50 VS

2.5

2.000      2.500      3.000       3.500

33           40           45            50

30           36           41            46

1.25/ 2.5*  1.5/ 3.0*   1.7/ 3.4*   1.92/ 3.8*

       37

     38

 2.000        2.500       3.000       3.500

 42             52             61            71

38.2         47.3          55.5        64.5

1.5/ 3.0*    1.9/ 3.8*    2.3/ 4.6*    2.7/ 5.4*

38                               40

150

10.9V

17V    (12V)  ,      22.7V       31.5V   (24V)

Содержание TD35 VS

Страница 1: ...PROCOLD S r l ITALY 13043 CIGLIANO VC C so Umberto 58 Tel 39 0161 42 44 52 Fax 39 0161 42 40 92 www procold it info procold it TD35 VS TD50 VS Technical specifications Compressor for R134a 12 24V DC ...

Страница 2: ...rpm Capacity W Input Power W Operating Current A C O P W W 1 1 Sound Level dB A Vibrancy Acceleration m s2 0 65 Operating Voltage V DC Cooling Static or Fan cooling Lubricant Polyester Lube Vol ml 5 Weight kg 4 3 Weight of Controller kg 0 40 Motor Type BLDCM Refrigerant R134a Throttling Device Capillary Power V D C 12 24 Test conditions Evaporating Temp 23 3 Suction Temp 32 2 Condensing Temp 54 4 ...

Страница 3: ...are using 5 1 7 A Thermostat is connected between the termin al C and T of the electronic unit It will start or stop the running of compressor automatically 5 1 8 A Resistor can be connected between terminal C and T it allows you to adjust the speed of the compressor the relationship between the resist or and the compressor speed shown by Table 3 please see it in page 3 5 1 9 To ensure sufficient ...

Страница 4: ...ltage V 0 9 6 10 9 17 0 21 3 22 7 31 5 1 6 9 7 11 0 17 0 21 5 22 9 31 5 2 4 9 9 11 1 17 0 21 8 23 2 31 5 3 6 10 0 11 3 17 0 22 0 23 4 31 5 4 7 10 1 11 4 17 0 22 3 23 7 31 5 6 2 10 2 11 5 17 0 22 5 23 9 31 5 8 2 10 4 11 7 17 0 22 8 24 2 31 5 11 10 5 11 8 17 0 23 0 24 5 31 5 14 10 6 11 9 17 0 23 3 24 7 31 5 18 10 8 12 0 17 0 23 6 25 0 31 5 24 10 9 12 2 17 0 23 8 25 2 31 5 33 11 0 12 3 17 0 24 1 25 5...

Страница 5: ...he refrigeration system has been too heavily loaded or if the ambient temperature is high than 55 the controller will run too hot 4 Minimum motor speed error if the refrigeration system is too heavily loaded the motor speed is lower than 1850 rpm 3 Motor start error The rotor is blocked or the system pressure is too high 2 Fan over current cut out The operating current of cooling fan is more than ...

Страница 6: ...ressor the pressure in the compressor could not more than 0 49MPa 8 6 Do not operate the compressor before polyester is charged 8 7 The refrigerant charge should be less than 200g 8 8 The interval of compressor operation Operation is more than 3 minutes and the stoppage is more than 3 minutes too 8 9 Special attention Do not use the compressor as a vacuum pump and do not start it under vacuum stat...

Страница 7: ...VS TD50 VS PROCOLD S r l ITALY 13043 CIGLIANO VC C so Umberto 58 Tel 39 0161 42 44 52 Fax 39 0161 42 40 92 6 www procold it info procold it CONTROLLER COMPRESSOR PROCESS Ø 6 20 SUCTION Ø 6 20 DISCHARGE Ø 5 15 DIMENSIONS COMPRESSOR Rev 2 0 27 02 2019 ...

Отзывы: