3

5.2

The Technical Specification of controller is shown:

Table 2 Controller Data 

Compressor Model 

TD35 VS - TD50 VS

Model

12/24V DC

 

Dimensions 

116mm  ×  103mm  ×  50mm 

Output Power

20W~ 140W 

Static Consumption 

Power

Max. Ambient Temp.

55 

Max. Operating Current A

12A

12V ,

6A(24V) 

Controller 

Startup Time

6s

to 1850rpm

5.3

Compressor Speed Setting:

  The  compressor s  speed  could  be  adjusted  in  range  2000rpm

3500rpm  by  adjusting  the  

resistor of presetting speed

5.4

Battery Protection Setting:

Table 4      Battery Protection Setting 

Protect 

Resistor 

K

12V 

cut-out 

V

12V 

cut-in 

V

12V Max.

Voltage

V

24V 

cut-out

V

24V 

 cut-in

V

24V Max. 

voltage

V

0

 

    9.6

      10.9

      17.0

     21.3

  22.7

      31.5

 

1.6

      9.7

      11.0

      17.0

     21.5

  22.9

      31.5

 

2.4

      9.9

      11.1

      17.0

     21.8

  23.2

      31.5

 

3.6

     10.0

     11.3

      17.0

     22.0

   23.4

     31.5

 

4.7

     10.1

     11.4

      17.0

     22.3

   23.7

     31.5

 

6.2

     10.2

     11.5

      17.0

     22.5

   23.9

     31.5

 

8.2

     10.4

     11.7

      17.0

     22.8

   24.2

     31.5

 

11

     10.5

     11.8

      17.0

     23.0

   24.5

     31.5

 

14

     10.6

     11.9

     17.0

     23.3

   24.7

     31.5

 

18

     10.8

     12.0

      17.0

     23.6

   25.0

     31.5

 

24

     10.9

     12.2

      17.0

     23.8

   25.2

     31.5

 

33

     11.0

     12.3

      17.0

     24.1

   25.5

     31.5

 

47

     11.1

     12.4

      17.0

     24.3

   25.7

     31.5

 

82

     11.3

     12.5

      17.0

     24.6

   26.0

     31.5

 

PROCOLD S.r.l. - ITALY- 13043 CIGLIANO (VC)

C/so Umberto,58 - Tel (+39) 0161 42 44 52 Fax (+39)  0161 4 2 40 92 
                     www.procold.it      info@proco ld.it

220

    9.6

     10.9          Photovoltaic soalr appli cation

 31.5

 

Table  3      Speed  Setting     (Terminal C-T)

Resistor 

 Speed

rpm 

0

          2000

 

277

         2500

 

692

         3000

 

1523

         3500

 

White  Resistor  

Black  Resistor

Red     Resistor

+/-

0.1 V      (Terminal C-P) 

Rev. 2.0 27/02/2019

Содержание TD35 VS

Страница 1: ...PROCOLD S r l ITALY 13043 CIGLIANO VC C so Umberto 58 Tel 39 0161 42 44 52 Fax 39 0161 42 40 92 www procold it info procold it TD35 VS TD50 VS Technical specifications Compressor for R134a 12 24V DC ...

Страница 2: ...rpm Capacity W Input Power W Operating Current A C O P W W 1 1 Sound Level dB A Vibrancy Acceleration m s2 0 65 Operating Voltage V DC Cooling Static or Fan cooling Lubricant Polyester Lube Vol ml 5 Weight kg 4 3 Weight of Controller kg 0 40 Motor Type BLDCM Refrigerant R134a Throttling Device Capillary Power V D C 12 24 Test conditions Evaporating Temp 23 3 Suction Temp 32 2 Condensing Temp 54 4 ...

Страница 3: ...are using 5 1 7 A Thermostat is connected between the termin al C and T of the electronic unit It will start or stop the running of compressor automatically 5 1 8 A Resistor can be connected between terminal C and T it allows you to adjust the speed of the compressor the relationship between the resist or and the compressor speed shown by Table 3 please see it in page 3 5 1 9 To ensure sufficient ...

Страница 4: ...ltage V 0 9 6 10 9 17 0 21 3 22 7 31 5 1 6 9 7 11 0 17 0 21 5 22 9 31 5 2 4 9 9 11 1 17 0 21 8 23 2 31 5 3 6 10 0 11 3 17 0 22 0 23 4 31 5 4 7 10 1 11 4 17 0 22 3 23 7 31 5 6 2 10 2 11 5 17 0 22 5 23 9 31 5 8 2 10 4 11 7 17 0 22 8 24 2 31 5 11 10 5 11 8 17 0 23 0 24 5 31 5 14 10 6 11 9 17 0 23 3 24 7 31 5 18 10 8 12 0 17 0 23 6 25 0 31 5 24 10 9 12 2 17 0 23 8 25 2 31 5 33 11 0 12 3 17 0 24 1 25 5...

Страница 5: ...he refrigeration system has been too heavily loaded or if the ambient temperature is high than 55 the controller will run too hot 4 Minimum motor speed error if the refrigeration system is too heavily loaded the motor speed is lower than 1850 rpm 3 Motor start error The rotor is blocked or the system pressure is too high 2 Fan over current cut out The operating current of cooling fan is more than ...

Страница 6: ...ressor the pressure in the compressor could not more than 0 49MPa 8 6 Do not operate the compressor before polyester is charged 8 7 The refrigerant charge should be less than 200g 8 8 The interval of compressor operation Operation is more than 3 minutes and the stoppage is more than 3 minutes too 8 9 Special attention Do not use the compressor as a vacuum pump and do not start it under vacuum stat...

Страница 7: ...VS TD50 VS PROCOLD S r l ITALY 13043 CIGLIANO VC C so Umberto 58 Tel 39 0161 42 44 52 Fax 39 0161 42 40 92 6 www procold it info procold it CONTROLLER COMPRESSOR PROCESS Ø 6 20 SUCTION Ø 6 20 DISCHARGE Ø 5 15 DIMENSIONS COMPRESSOR Rev 2 0 27 02 2019 ...

Отзывы: