Keycar
d Available
Maximum A
ddresses
Minimum A
uthor
ization
Re
quired
Selectable Expir
y
Factory D
efault Expir
y
Varia
ble Ex
piry
Gu
est C
ommon A
reas
Salesman's Lockout
Staff Com
mon Are
as
Time Zone On
Keycar
d
Menus Navigation & Options
1
Guest
Yes
16,000
FDA
1 hr to 2730 night
s
1 nigh
t
Yes
8
Yes
-
FDA/1/1/Room#...
2
One-Shot
Yes
16,000
FDA
1 hr to 4 hr
s
1 h
r
No
-
N
o
-
FDA/1/2/Room#... For Guest Rooms only
3
Adjoining Suite
Yes
16,000
FDA
1 hr to 2730 night
s
1 nigh
t
Yes
8
Yes
-
FDA/1/3/Starting Room#...
4
Common Door Suite
Yes
1,000
FDA
1 hr to 2730 night
s
1 nigh
t
Yes
8
Yes
-
FDA/1/4/Suite#...
5
Convention Suite
Yes
1,000
FDA
1 hr to 2730 night
s
1 nigh
t
Yes
8
Yes
-
FDA/1/5/Convention Suite#...
6
Pre-registered
Yes
16,000
FDA
1 hr to 2730 night
s
1 nigh
t
Yes
8
Yes
-
FDA/1/6/Guest or Adj. or Comm. Door...
7
Restricted Area
Yes
200
G
MA
1 night to 2730 night
s
1 nigh
t
No
-
N
o
-
G
MA
/1
/7
/#
...
8
Section
Yes
255
MA
1 night to 2730 night
s
365 night
s
-
***
**
16
6
MA/1/8/Section#...
9
Floor
Yes
255
MA
1 night to 2730 night
s
365 night
s
-
***
**
16
6
MA/1/9/Floor#...
10
Group
Yes
255
MA
1 night to 2730 night
s
365 night
s
-
***
**
16
6
MA/1/10/Group#...
11
Zone
Yes
255
MA
1 night to 2730 night
s
365 night
s
-
***
**
16
6
MA/1/1 1/Zone# ...
12
Area
Yes
255
MA
1 night to 2730 night
s
365 night
s
-
***
**
16
6
MA/1/12/Area#...
13
Bellman's Master
Yes
1
BA/GMA
1 hr to 24 hr
s
24 hrs
-
None
**
None
A
ll
BA or GMA/1/13
14
Grand Master
Yes
1
GMA
1 night to 2730 night
s
365 night
s
-
A
ll
**
A
ll
A
ll
GMA/1/14
15
Emergency
Yes
1
G
MA
1 night to 2730 night
s
365 night
s
-
A
ll
†
A
ll
A
ll
GMA/1/15
16
Front Desk (FDA)
No
100
MA
None
-
-
-
-
-
-
MA/1/16
17
Bellman's (BA)
No
40
GMA
None
-
-
-
-
-
-
GMA/1/17
18
Programming (PA)
No
20
GMA
None
-
-
-
-
-
-
GMA/1/18/2
18
Master (MA)
No
20
GMA
None
-
-
-
-
-
-
GMA/1/18/1
19
Grand Master (GMA)
No
20
GMA
None
-
-
-
-
-
-
GMA/1/19
30
POS
Yes
200
MA
None
-
-
-
-
-
-
MA/1/30
*
Salesman's
-
-
FDA
-
-
-
-
-
-
-
Not a keycard*
20
Hotel
No
1
GMA
1 hr to 2730 night
s
24 hrs
-
-
-
-
-
GMA/1/20
21
Room
No
16,000
GMA
1 hr to 24 hr
s
24 hrs
-
-
-
-
-
GMA/1/21
22
Group
No
255
MA
1 night to 2730 night
s
365 night
s
--
-
-
-
MA/1/22 for locking out guests who have checked out.
23
Battery Test
No
A
ll
FDA
None
-
-
-
-
-
-
FDA/1/23
24
Programmiing
No
A
ll
PA
1 night to 2730 night
s
2730 night
s
--
-
-
-
PA/1/24
25
Passage
Yes
16,000
MA
1 night to 2730 night
s
1 nigh
t
--
-
-
-
MA/1/25
26
Hotel Restart
No
1
GMA
1 hr to 24 hr
s
24 hrs
27
FDU Cancel
No
1
GMA
1 hr to 24 hr
s
24 hrs
28
Installation
(1)
Test
No
1
P
A
None
-
-
-
-
-
-
PA/1/28/1 Expiry 2730 nights recommended
(2)
Initialization
No
1
P
A
None
-
-
-
-
-
-
PA/1/28/2
31
Audit Lock
No
1
P
A
None
--
-
-
-
-
PA/1/31 SolitaireSMART only
* The Salesman's Lockout is not a keycard but rather an option on the Guest or Suite keycard (consult the manual).
** Will not override the Salesman's Lockout, Room or Hotel Lockout, or deadbolt.
*** The FDU features can be set to encode access to either all 8, or none of the Guest Common Areas on Sub-Master level (Staff
) Keycards.
† Will override the Salesman's Lockout, Room or Hotel Lockout, or deadbolt.
CALL KABA ILCO SERVICE LINE FOR ASSISTANCE
Lockout / Unlock
Special Purpose
Master Level Access
Authorization
Appendix A: Keycard Quick Reference Guide
Sub-Master Level Access
Guest Level Access
Rest. Area Level Access
Содержание ILCO FDU
Страница 1: ...PK3514_06_07 USER S GUIDE Next Generation FDU ...
Страница 3: ...ii Kaba Ilco Lodging Access Control System ...
Страница 10: ...ix Kaba Ilco Lodging Access Control System ...
Страница 11: ......
Страница 243: ......
Страница 245: ......
Страница 258: ......
Страница 260: ......
Страница 269: ......