Chapter 5
132
Kaba Ilco Lodging Access Control System
Flashing Green & Red
Low battery indicator when using Staff keycard.
Change the battery
(see Section 11.4 – Replacing a
Battery)
.
Single Green & Red
Low battery indicator when using Battery Test
keycard.
Change the battery
(see Section 11.4 – Replacing a
Battery)
.
Green, then Red (locks)
Lock not programmed or card misread.
Try again. If this response continues, troubleshoot
the card and/or lock.
Single green, then Red
(RACs only)
Passage activated and out of time zone.
Red
LED
always
on
Halt Mode (Batteries are too low to continue
operation).
Batteries need to be changed. *
Red LED flashes every
half second
Power-on or reset while mechanical override is on.
Disengage mechanical override & reconnect the
batteries (cam not engaged).
Double short flash of
Red LED every 4 sec.
Advanced fail mode (memory failure).
Lock circuit board needs to be changed.
Green and Red (single
flash together) then green
once
Successful initialization.
Green and Red (single
flash together) then red
once
Unsuccessful initialization.
Green and Red together
(single flash together for
6 seconds)
Test card.
Can also happen during installation. Solution: Disconnect the batteries, wait 5
seconds and reconnect the batteries.
5.3
Programming Locks and Remote Access Controllers
Locks and RAC’s have the same or similar functions in the system, and are programmed
in the same way, with the exception of flexible Time Zones available in RAC models 3.5,
Содержание ILCO FDU
Страница 1: ...PK3514_06_07 USER S GUIDE Next Generation FDU ...
Страница 3: ...ii Kaba Ilco Lodging Access Control System ...
Страница 10: ...ix Kaba Ilco Lodging Access Control System ...
Страница 11: ......
Страница 243: ......
Страница 245: ......
Страница 258: ......
Страница 260: ......
Страница 269: ......