Locks – Using and Programming
Kaba Ilco Lodging Access Control System
155
Zones). One of the eight Time Zones (1-8) or no time zone (0) can be selected for each of
the following types of keycards when the RAC is programmed:
Time Zone Level
Applicable Keycards
Guest keycards
Guest, One-shot, Adjoining Suite, Common Door Suite
and Convention Suite
Staff access keycards
Section, Floor, Group, Zone, Area, Bellman's Master
and Grand Master
Passage mode
Passage
Using these time zones, RACs, which are often used for common areas such as a pool or
other amenities or in other high traffic situations, can be customized to offer a higher
degree of security based on the hours when access should be permitted. Guest, Staff, and
Passage Mode access can all be restricted individually on each card reader.
NOTE: The six Fixed Time Zones that are encoded on Staff Sub-master level key-
cards to restrict access to other locks are not available on the RAC.
5.5.1
Guest and Staff Level Flexible Time Zones
When an otherwise valid entry keycard is swiped in the card reader of RAC Models 3.5,
4 or 4XT 4 at a time of day that does not fall in one of the intervals of the selected time
zone, access will be denied, and the red indicator will flash once. If no time zone is
selected, the RAC will accept valid keycards regardless of the time of day. The use of the
Emergency keycard is not restricted by time zones. Staff and Guest access can be
controlled by the same or different time zones.
5.5.2
Passage Mode Level Flexible Time Zone
The Passage keycard is used in the normal way when a Passage Time Zone is selected.
The RAC is put in Passage mode by inserting a valid Passage keycard once. The RAC
remains in Passage mode until the Passage Time Zone interval ends, or until a Passage
keycard is swiped a second time in the reader of the RAC. The remainder of the time, a
keycard will be required to gain access to the RAC.
5.5.3
Programming Flexible Time Zones
Purpose:
To associate a Flexible Time Zone with a type of
keycard (Guest, Staff or Passage) in the programming
of RAC Models 3.5, 4 & 4XT. The addresses and the
time zones can be programmed in one operation.
Содержание ILCO FDU
Страница 1: ...PK3514_06_07 USER S GUIDE Next Generation FDU ...
Страница 3: ...ii Kaba Ilco Lodging Access Control System ...
Страница 10: ...ix Kaba Ilco Lodging Access Control System ...
Страница 11: ......
Страница 243: ......
Страница 245: ......
Страница 258: ......
Страница 260: ......
Страница 269: ......