Table 83: Chassis Component Alarm Conditions on QFX10000 Modular Models
(Continued)
Chassis
Component
Alarm Condition
Alarm
Severity
Remedy
One of the fan tray controller in
the chassis is not receiving
enough power.
Major (red)
Check the power supply.
Switch Interface
Boards (SIBs)
One of the SIB has failed.
Minor
(yellow)
Check the below:
•
The SIB is not receiving power.
•
The fan tray controller is having a
power problem.
SATA SSD slot
The SSD has failed or removed.
Major (red)
Install the SSD.
Ethernet
The Ethernet management
interface on the Control board
is down.
Minor
(yellow)
•
Check the interface cable connection.
•
Reboot the system.
•
If the alarm recurs, open a support
case using the Case Manager link at
https://www.juniper.net/support/
or
call 1-888-314-5822 (toll free, US &
Canada) or 1-408-745-9500 (from
outside the United States).
Hot swapping
Too many hot-swap interrupts
are occurring.
Major (red)
Replace the failed components.
Power supplies
A power supply has been
removed from the chassis.
Minor
(yellow)
Install a power supply in the empty slot.
A power supply has a high
temperature.
Major (red)
Replace the failed power supply.
A power supply input has failed.
Major (red)
Check power supply input connection
and the power cord.
359
Содержание QFX10016
Страница 1: ...QFX10016 Switch Hardware Guide Published 2022 09 09...
Страница 10: ...Compliance Statements for Environmental Requirements 428 x...
Страница 15: ...Figure 1 on page 5 shows a front and rear view of the QFX10016 4...
Страница 16: ...Figure 1 QFX10016 Front and Rear 5...
Страница 175: ...Installing the QFX10008 into a Rack Mounting a QFX10016 in a Four Post Rack Using a Mechanical Lift 207 164...
Страница 239: ...RELATED DOCUMENTATION QFX10008 Installation Overview QFX10002 System Overview 228...
Страница 266: ...CAUTION Do not bump the output connections If the connection hits a solid object it could damage the power supply 255...
Страница 270: ...1 ESD point Figure 113 ESD Point on QFX10016 Chassis Rear 1 ESD point 259...
Страница 287: ...Figure 130 Installing a JNP10K PWR AC2 in a QFX10016 276...
Страница 322: ...Figure 159 Installing a JNP10K PWR DC2 in QFX10016 311...
Страница 366: ...5 CHAPTER Troubleshooting Troubleshooting QFX10000 Modular Chassis 356...