• Major (red)—Indicates a critical situation on the device that has resulted from one of the conditions
. A red alarm condition requires immediate action.
• Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left unchecked, might
cause an interruption in service or degradation in performance. A yellow alarm condition requires
monitoring or maintenance.
describes the chassis alarm messages on QFX10000 modular chassis switches.
Table 83: Chassis Component Alarm Conditions on QFX10000 Modular Models
Chassis
Component
Alarm Condition
Alarm
Severity
Remedy
Control board
A Control board has failed.
Major (red)
Replace the failed Control board.
A Control board has been
removed.
Minor
(yellow)
Install a Control board in the empty slot.
Line Cards
A line card is offline.
Minor
(yellow)
Check the line card. Remove and reinstall
the line card. If this fails, replace the
failed card.
A line card has failed.
Major (red)
Replace the failed line card.
A line card has been removed.
Major (red)
Install a line card in the empty slot.
Fan trays
A fan tray has been removed
from the chassis.
Major (red)
Install the missing fan tray.
One fan in the chassis is not
spinning or is spinning below
required speed.
Major (red)
Replace the fan tray.
A fan is not receiving power
from the fan tray controller.
Major (red)
Check and replace the failed fan tray
controller if required.
Fan Tray
Controller
A fan tray controller has failed.
Minor
(yellow)
Check and replace the failed fan tray
controller if required.
358
Содержание QFX10016
Страница 1: ...QFX10016 Switch Hardware Guide Published 2022 09 09...
Страница 10: ...Compliance Statements for Environmental Requirements 428 x...
Страница 15: ...Figure 1 on page 5 shows a front and rear view of the QFX10016 4...
Страница 16: ...Figure 1 QFX10016 Front and Rear 5...
Страница 175: ...Installing the QFX10008 into a Rack Mounting a QFX10016 in a Four Post Rack Using a Mechanical Lift 207 164...
Страница 239: ...RELATED DOCUMENTATION QFX10008 Installation Overview QFX10002 System Overview 228...
Страница 266: ...CAUTION Do not bump the output connections If the connection hits a solid object it could damage the power supply 255...
Страница 270: ...1 ESD point Figure 113 ESD Point on QFX10016 Chassis Rear 1 ESD point 259...
Страница 287: ...Figure 130 Installing a JNP10K PWR AC2 in a QFX10016 276...
Страница 322: ...Figure 159 Installing a JNP10K PWR DC2 in QFX10016 311...
Страница 366: ...5 CHAPTER Troubleshooting Troubleshooting QFX10000 Modular Chassis 356...