For installation of multiple dimmers above or next to each other
Reduction for the outer devices by 10 percent and by 20 percent for the inner devices
Example
:
Installation of 3 dimmers, each with 500 watts, in a multiple combination
Reduction of the rated load by 10
percent or 20 percent
The two outer 500 W dimmers may only be loaded with 90 percent of the specified rated
power, i.e. with
450
W
.
The inner 500 W dimmer may only be loaded with 80 percent of the specified rated power,
i.e. with
400
W
.
If several of these conditions occur together in an installation, the rated power must be further
reduced accordingly.
92