Doc. No.: 103839 Rev. A
jotron.com
Page 70 of 104
10.3.3.3
Output Power
The button “Output Power” will toggle between “High” and “Low” power:
(12.5 Watts)
(1 Watt )
10.3.3.4
Transition Zone
A Region must be between 20 an 200 Nautical miles and within this region there will be a “Transition zone”
between 1 and 8 Nautical miles:
This zone is used for frequency transition so only one
frequency is changed at a time. There are defined rules for
how the AIS will behave through this zone.
The AIS will continuously monitor for its own position and
range to the regional areas defined.
When entering transition zone for Region 1, frequency is
changed on the primary channel. The AIS is now sending
the primary frequency defined for each of the regions.
When the boundary for the Region 1 is crossed, the second
frequency shall be changed. Then the primary frequency
for the old region (or default setting) is switched with the
secondary frequency for the new region. Then both frequencies have changed.
When entering another region, frequency transition is performed as described above with the frequencies
(settings) of the new region. When leaving a region, frequency transition is performed back to default values.
To change the value of this “Transition Zone”, select the button and input value between 1
and 8 (Nautical miles)