background image

Aprisa SR+ Protected Station Quick Start Guide 1.4.0  © 2021 4RF Limited. All rights reserved. This document is protected by copyright belonging to 4RF 
Limited  and  may  not  be  reproduced  or  republished  in  whole  or  part  in  any  form  without  the  prior  written  permission  of  4RF  Limited.  While  every 
precaution has been taken in the preparation of this literature, 4RF Limited assumes no liability or errors and omissions, or from any damages resulting 
from use of this information. The contents and any product specifications within it are subject to revision due to ongoing product improvements and 
may change without notice. Aprisa and the 4RF logo are trademarks of 4RF Limited. All other marks are the property of their respective owners. 
 

5. Set up the Aprisa SR+ Protected Station 

Login  using  the  IP  address  of  either  the  primary  or  secondary  radio 
(do  not  use  the  PVIP  address  for  login).  All  parameters  will  be 
automatically synchronized on both radios. 

The  Aprisa  SR+  has  a  factory  default  Terminal  Operating  Mode  of 
Remote Station. 

A single radio or a protected station in the Aprisa SR+ network must 
be setup as a base station. The other radios or protected stations in 
the  Aprisa  SR+  network  are  setup  as  remote  stations  or  repeater 
stations. 

Set the Ethernet Operating Mode and the Compliance Mode required. 

 

Set  the  unique  radio  Network  ID  to  be  the  same  in  your  entire 
network including the Base Station ID. 

 

Set  the  Aprisa  SR+  TX  Frequency,  RX  Frequency,  TX  Power  and 
Channel Size to comply with your site license. 

Set the Antenna Port Configuration required. 

 

You can now configure the remaining protected station and network parameters and settings. For more information, please refer to the Aprisa 
SR+ User Manual available from the 4RF websit

https://www.4rf.com/secure

 (login required). 

 

Reboot both Primary and Secondary radios and restore the Hardware Manual Lock switch is set to AUTO. 

The Aprisa SR+ Protected Station is ready to operate.  

 

6. Monitor the Aprisa SR+ Protected Station signal strength 

When  the  network  is  installed,  the  radio  signal  strength  can  be 
monitored on remote stations by setting the radio to Test Mode. 

To  enter  Test  Mode,  press  and  hold  the  TEST  button  on  front  panel 
until all the LEDs flash green (about 3 - 5 seconds). 

In  Test  Mode,  the  LED  Display  panel  presents  a  real  time  visual 
display  of  the  RSSI.  This  can  be  used  to  adjust  the  antenna  for 
optimum signal strength. 

Note: The response time is variable and can be up to 5 seconds. 

To exit Test Mode, press and hold the TEST button until all the LEDs 
flash red (about 3 - 5seconds). 

If the network is operating correctly, the LEDs will show: 

 

Active radio - the OK, MODE and AUX LEDs will be light green 

and the TX and RX LEDs will be solid or flash green.  

 

Standby  radio  -  the  OK  will  light  green,  the  MODE  LED  will 

light orange, the AUX LED will light green and the TX and RX 
LEDs will light green (steady). 

 

 

Quick Start Guide 

Aprisa SR+ Protected Station 

Contents 
 
Follow these steps to setup your Aprisa SR+ Protected Station: 

 

1.

 

Check the box contents 

2.

 

Install the Aprisa SR+ protected station and connect the protection earth 

3.

 

Connect the antenna and apply power to the Aprisa SR+ protected station 

4.

 

Connect to the Aprisa SR+ protected station 

5.

 

Set up the Aprisa SR+ protected station 

6.

 

Monitor the Aprisa SR+ protected station signal strength 

Отзывы: