Doc. No.: 103839 Rev. A
jotron.com
Page 49 of 104
8.3.2.3
Power connection
Table showing connection of main and backup power
See also Figure 8-13
Allowed voltage levels of the power supply to be connected with the transponder:
Minimum = 10.8 volt
Maximum = 31.2 volt
Recommended cable diameter: 2.5 – 4 mm
2
Connection Symbol on PCB Function
P1
Chassis symbol
GND (Chassis)
P2
M -
MAIN 0V
P3
M +
MAIN 12 - 24 VDC
P4
Chassis symbol
GND (Chassis)
P5
B -
BACKUP 0V
P6
B+
BACKUP 12 – 24 VDC
Figure 8-8-16 Use the supplied orange