Input the “Admin Password” (SE) into the field and
press the “Confirm” button:
Then it is possible to access all fields and configure IP settings:
Default values are:
Display:
Adress: 10.0.0.11
Mask: 255.255.0.0
Transponder:
Adress: 10.0.0.10
Mask: 255.255.0.0
Gateway: 0.0.0.0
(Gateway is only used if Transponder and display are on different subnets)
And when configuration is finished either of “Return” or “Confirm”
buttons will bring you back to last
menu.
10.6.1.2
External display
The Transponder supports multiple ports for external
display, see chapter 8.3.2.5.
The serial ports are always enabled, therfore this
option is not shown in the configuration window, any
more. The Ethernet UDP may be enabled and work
at the same time as the serial ports.
When using UDP, the datagram is transmitted to the
IP address shown in the dialog. The address may be
in another subnet if a gateway is programmed in the
interface settings.
If Ethernet is used, an external Ethernet switch is required for simultaneously connection of the display unit and a
remote computer, see also chapter 8.3.2.5 which describes the External Display physical connections.