Doc. No.: 103839 Rev. A
jotron.com
Page 88 of 104
Missing SOG
Not transmissing SOG
The Transponder continues operation using default data.
Check wiring and external sensor.
Check baud rate settings.
Missing Heading
Not transmitting Heading
The Transponder continues operation using default data.
Check wiring and external sensor.
Check baud rate settings.
Missing ROT
Not transmitting Rate of
Turn
The Transponder continues operation using default data.
Check wiring and external sensor.
Check baud rate settings.
3013 C
Doubtful GNSS
Int/Ext GNSS position
mismatch
The Transponder continues operation, but as this might imply
that wrong position is used. Care should be taken as this
might impose a risk both for own and other ships.
Check the positioning of the GNSS antennas.
Disconnect the External GNSS and check if the internal
GNSS provides the correct position.
Doubtful heading Difference with COG
exceeds limit
The Transponder continues operation.
Alarm indicates mismatch between Course over ground and
True heading. Check sensors. If current speed is <5knots,
check SOG
3019 C
Wrong NavStatus Check NavStatus setting
The Transponder continues operation.
Check that navigational status is not at anchor, moored or
aground while SOG > 3knots.
Check that navigational status is not under way while SOG =
0 knots.
Check that SOG is correct.
3009 C
Lost MKD
Cannot display safety
related messages
The Transponder continues operation, and alerts other AIS
systems that no display is present.
Check that the display is turned on.
Check that the cable is correct connected in both ends.
Check the IP address and corresponding communications IP
address of both units if using the Ethernet connection.
Check for firewall error or such if connected through a local
network.
The following alarms are Jotron specific, and not part of IEC 61993-2:Ed3
1051 W
EEProm error
Configuration reset
Validation of internal configuration failed on boot, and
configuration has been reset. Attempt to re-configure unit and
reboot to see if configuration is kept. If not, service is
required.
1053 W
Invalid
dimensions
Check antenna ref.
Antenna reference is either invalid, length or beam of ship is
zero, or there is a mismatch in the length or beam of ship
between the internal and external antenna reference. Check
antenna reference page.
Table 7: Integrity alert conditions signaled using ALF sentence formatter.
1
.) The Tx/Rx Alarm is activated if one of the internal frequency generators is out of lock, making the transmitter or receiver
unable to function at the correct frequency.