SECTION 7 - BASIC ELECTRICAL INFORMATION & ELECTRICAL SCHEMATICS
31215031
7-5
AMP Mini Fit Jr
This connector system is typically used on control mod-
ules at JLG. Follow the general guidance for installation.
Mini Fit Sr
This connector system is typically used on control mod-
ules at JLG. Follow the general guidance for installation.
DIN Connectors
This connector is typically used on hydraulic valves. Fol-
low the installation instructions
Exceptions
Some waterproof connector applications do benefit
from dielectric grease, and some non waterproof con-
nectors do not benefit from dielectric grease.
In the exceptions below, we have found dielectric
grease is not needed for some applications, and in some
cases can interfere with the intended connection.
Dielectric grease shall be used as an exception in other
applications.
Enclosures
Application of dielectric grease is not required in prop-
erly sealed enclosures. To meet criteria, the enclosure
must be rated to at least IP56 (dust protected; protected
from powerful jets of water).
Carling Switch Connectors
Carling switches may experience high impedance, or dis-
continuity, due to silicone dielectric grease ingress when
switching inductive loads. Therefore, dielectric grease
shall not be applied to Carling switch mating connectors
unless specifically noted.
Improper
Proper
Improper
Proper
Improper
Proper